Search results for "Volume change"
showing 5 items of 5 documents
Volume change behaviour of a compacted scaly clay during cyclic suction changes
2010
The research presented in this paper focuses on the investigation and modelling of the volume change response of compacted tectonised clay samples subjected to several wetting and drying cycles in controlled-suction oedometers. Oedometer tests were carried out under different values of constant vertical net stress, and wetting and drying cycles were performed varying applied matric suction between 10 and 800 kPa. The investigation was complemented with a study of the material microstructure to support the interpretation of the overall mechanical response. At a microscopic level, the material is characterized by different types of particle assemblages, scales, and clay aggregates. One of th…
Advances in the Testing of the Hydro-mechanical Behaviour of Shales
2013
The paper presents some of the advanced experimental techniques and apparatuses that have been developed by the authors for testing the hydromechanical behaviour of shales. A methodology established for the analysis of the water retention behaviour in non-isochoric conditions is introduced; the method allows for the determination of the main drying and wetting paths in addition to the volume change response upon total suction variations. A high-pressure oedometric cell is then presented; the apparatus allows for the analysis of the transition from the pre-yield behaviour to the normally consolidated state. The analysis of the settlement versus time curves yields information on the permeabil…
Volume Changes in Filled Rubber Under Uniaxial Cyclic Loading
2011
Styrene-butadiene rubber, neat and filled with different silica content was investigated under uniaxial cyclic loading under a constant crosshead speed, with increasing deformation amplitude in subsequent loading cycles. Rubber was investigated in order to evaluate the reversibility of structure rearrangements, occurring in rubber when subjected to cyclic loading. Volume uniformly increases with growing strain and shows hysteresis at unloading. After complete unloading, no residual strain changes are observed. These data are in good conformity with the data of density measurements, which were made on specimens before and after the tests. By correlating data, obtained from volume changes and…
Quantitative criteria for the diagnosis of the congenital absence of pericardium by cardiac magnetic resonance
2015
Congenital absence of the left ventricular pericardium (LCAP) is a rare and poorly known cardiac malformation. Cardiac Magnetic Resonance (CMR) is generally used for the diagnosis of LCAP because of its high soft tissue contrast, multiplanarity and cine capability, but the diagnosis is usually made by only qualitative criteria. The aim of the present study was to establish quantitative criteria for the accurate diagnosis of LCAP on CMR.We enrolled nine consecutive patients affected by LCAP (mean age 26±8years, 7 males), 13 healthy controls, 13 patients with dilated cardiomyopathy (DCM), 12 patients with hypertrophic cardiomyopathy (HCM) and 13 patients with right ventricular overload (RVO).…
Electromechanical coupling in anodic niobium oxide: Electric field-induced strain, internal stress, and dielectric response
2012
Seemingly, contradictory results have been reported so far for electrostriction in anodic oxides. Furthermore, no definitive agreement could be obtained with theory. In this paper, in situ techniques are combined to elucidate electrostriction in anodic niobium oxide. The dependence of strain, internal stress, and dielectric constant on the electric field is measured by, respectively, spectroscopic ellipsometry, curvature, and impedance measurements. The through-thickness strain is tensile and proportional to the square of the electric field. The in-plane internal stress is compressive and proportional to the square of the electric field at low field values. The internal stress is predicted …